P840 series are specially designed for the ultra-high purity gas distribution system used in a semiconductor, electronic, medical, biotechnology and pharmaceutical industry.
| Nominal diameter | 50 mm(2″) |
| Switch point accuracy | ±2.0% of full scale |
| Scale range | 0 ~ 28 MPa |
| Working Pressure | Steady pressure : 75% of full scale value Fluctuating pressure : 67% of full scale value |
| Working temperature | Ambient : -40 ~ 65°C Fluid : Max. 100°C |
| Temperature effect | Accuracy at temperature above and below the reference temperature (20℃) will be effected by approximately ±0.4% per 10℃ of full scale |
| Pressure connection | Type 316L stainless steel electropolished low mount or center back mount surface finish Ra≤0.25 ㎛ ¼” NPT male thread VCRⓡ male or female face seal fitting |
| Element | 316L SS < 6 MPa : C-type bourdon tube ≥6 MPa : Helical type bourdon tube |
| Case | 304SS, Electropolished with pressure relief |
| Cover and window | Twist-lock polycarbonate |
| Movement | Stainless steel |
| Pointer | Black painted aluminium alloy |
| Dial | White PVC, with pointer stop pin With black/red lettering, dual pressure scale (bar) |
| Helium leak rate | Tested to confirm leakage rates of less than 10-9 mbar • ℓ/sec |
| Connection | 26 AWG, PVC 10 feet (3 m) leads (2 black wires) |
| Maximum switching current | 0.5 amps AC/DC noninductive load |
| Maximum power | 10 W/DC, 12 VA/AC |
| Maximum switching voltage | 28 V AC/DC |