P690 differential pressure gauge series are designed to measure differential pressure from 25 kPa to 2.0 MPa at static pressure up to 10 MPa and have inductive contact. P690 series are designed to control alarm for differential pressure, providing the right time to replace air and sludge filter during the process.
| Nominal diameter | 160 mm |
| Accuracy | ± 1.6% of full scale |
| Scale range (MPa, kPa, bar) | 0 ~ 25 kPa to 0 ~ 0.2 MPa 0 ~ 0.25 MPa to 2.0 MPa |
| Static pressure | Max. 10 MPa |
| Working temperature | Ambient : -20 ~ 65°C -40 ~ 65°C (With silicone filling) Fluid : Max. 100°C |
| Degree of protection | EN60529/IEC529/IP65 |
| Temperature effect | Accuracy at temperature above and below the reference temperature (20℃) will be effected by approximately ±0.5% per 10℃ of full scale |
| Pressure connection | Stainless steel (316SS) |
| Element | Bellows Stainless steel (316L SS) |
| Case and cover | Stainless steel (304SS) Bayonet type |
| Dial | White aluminium with black graduations |
| Window | Polycarbonate |
| Pointer | Black painted aluminium alloy |
| Contact | Inductive contact |
| Conduit connection | M20 x 1.5P |
| Process connection | ¼” NPT(F) ½” NPT(F) at 3-way and 5-way manifold valve |
| Standard accessories | Mounting bracket for 2” pipe mounting with silver gray finished steel |
| Certificates | NEPSI Ex ia IIC T6 Ga Tamb = -25 ~ 56ºC |
| Option | Remote seal ½” (N)PT female conduit connection ¾” (N)PT female conduit connection Mounting bracket with 316SS for 2″ pipe mounting 3-way manifold valve (316SS) 5-way manifold valve (316SS) 3-way manifold valve (Monel) 5-way manifold valve (Monel) |